Longrange Wiegand Data Interpreters
Specifications & Capabilities
Powering the Device
The PPE Longrange Wiegand Data Interpreters come fully assessembled and ready for use. Simply connect your power source (12VDC Recommended) to the 5.5x2.1mm male barrel connector. Upon supplying power, the reader and Doppelgänger will boot up.
While the Doppelgänger Breakout Board states that the maximium input voltage is 15V, you can supply up to 28VDC ONLY IF YOU USE ACTIVE COOLING on the LDO (chip indicated by the HOT symbol). Additionally, the power input is a passthrough circuit. This means that whatever voltage you supply to the Doppelgänger Breakout Board will be passed through to your reader. Ensure that your reader is rated for the voltage that you intend to supply. Do this at your own risk!
Configuring the Device
To configure the deivice, follow the instructions provided in the Doppelgänger Guide.
Internal Wiring View
R90SE